Development and diagnostic accuracy of a ratio-based multivariable CT imaging model for regional periarticular knee osteoporosis classification.

Klinger CE, Mueller MM, Bilodeau RE, Sculco TP, Sculco PK.
Clinical imaging · 2026-09-21 · PMID 42790016

文献摘要

Purpose To compare the diagnostic performance of CT-derived attenuation-based and ratio-based imaging biomarkers for region-specific knee osteoporosis. Methods This retrospective diagnostic accuracy study included consecutive adults with knee CT and standing long-leg radiographs from a single academic institution. Exclusion criteria included prior ipsilateral fracture or surgery, incomplete periarticular coverage, non-standard acquisition parameters, age Results The cohort included 288 adults (mean age 67.1 ± 9.0 years; 50% female); 42.0% had osteoporosis in at least one region. The combined attenuation-plus-ratio model (Model 1) demonstrated outstanding apparent discrimination for any-region (AUC 0.940), distal femoral epiphysis (0.927), and proximal tibial epiphysis osteoporosis (0.957), with significantly higher AUCs than ratio-only models (p Conclusion Adding DFM attenuation to ratio-based CT models improved apparent discrimination in this cohort, whereas ratio-only models preserved substantial regional diagnostic information. External, multi-scanner validation is needed before clinical implementation.