知镜 Cognispect · 医学文献与研究工作台

Diagnostic Accuracy and Preliminary Psychometric Validation of the Spanish Stanford Proxy Test for Delirium in Nonintubated Mexican Intensive Care Unit and Intermediate Care Patients.

Arnaud-Gil CA, Fresan A, Gunther M, Cabrales-Lozano JA, Frausto-Gonzalez JC, Alvizo-Garcia PG, Hernandez-de-Leon JE, Medina-Graciano C, Barrenechea-Quijano G, Lopez-Salinas A, Maldonado JR.
Journal of the Academy of Consultation-Liaison Psychiatry · 2026-09-19 · PMID 42763037

文献摘要

Background Delirium remains frequently underrecognized in critically ill patients. Although the Spanish Stanford Proxy Test for Delirium (S-PTD) has been previously evaluated, evidence regarding its diagnostic performance and psychometric properties in Mexican intensive and intermediate care populations remains limited. Objective To evaluate the diagnostic performance, internal consistency, and construct validity of the Spanish Stanford Proxy Test for Delirium (S-PTD) in nonintubated critically ill Mexican patients admitted to intensive and intermediate care units. Methods We conducted a single-site cross-sectional psychometric study in adult patients admitted to intensive care and intermediate care units within the first 48 h of admission. Trained nursing staff administered the Spanish S-PTD at the end of the clinical shift, and results were compared with an independent delirium assessment performed by consultation-liaison psychiatrists using Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria. Patients with endotracheal intubation or Richmond Agitation-Sedation Scale scores ≤ -3 were excluded by protocol. Diagnostic accuracy, receiver operating characteristic curve performance, internal consistency, and exploratory factor structure were examined. Results A total of 120 patients were analyzed. Mean age was 62.5 ± 18.1 years, 64 (53.3%) were men, and 87 (72.5%) were admitted for medical conditions. Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition delirium was identified in 21 patients (17.5%), whereas 27 patients (22.5%) screened positive using the S-PTD cut-off of ≥3. At this cut-off, the S-PTD demonstrated an area under the receiver operating characteristic curve of 0.87, accuracy of 88.3% (95% confidence interval [CI], 81.4%-92.9%), sensitivity of 81.0% (95% CI, 60.0%-92.3%), specificity of 89.9% (95% CI, 82.4%-94.4%), positive predictive value of 63.0% (95% CI, 44.2%-78.5%), and negative predictive value of 95.7% (95% CI, 89.5%-98.3%). Internal consistency was high (Cronbach α = 0.948). Exploratory factor analysis provided preliminary evidence supporting construct validity and a predominantly unidimensional structure (Kaiser-Meyer-Olkin = 0.84; Bartlett test P Conclusions In this nonintubated intensive care unit/intermediate care unit Mexican cohort, the Spanish S-PTD demonstrated promising diagnostic accuracy and psychometric properties when administered by trained nursing staff. Findings should be interpreted cautiously because of the single-site design, limited number of delirium cases, exclusion of mechanically ventilated and moderately/deeply sedated patients, absence of formal inter-rater reliability testing, and the small number of patients with documented cognitive impairment or dementia. Further multicenter studies, including mechanically ventilated patients, are needed before broad implementation in critically ill populations.

在知镜精读原文来源DOI 原文

知镜提供医学文献检索、阅读笔记、人体图谱、统计绘图与研究复现工具。