Quality control stress test for deep learning-based diagnostic model in digital pathology

Schömig-Markiefka B, Pryalukhin A, Hulla W, et al.
Mod Pathol · 2021-06-24 · PMID 34168282

文献摘要

Digital pathology provides a possibility for computational analysis of histological slides and automatization of routine pathological tasks. Histological slides are very heterogeneous concerning staining, sections' thickness, and artifacts arising during tissue processing, cutting, staining, and digitization. In this study, we digitally reproduce major types of artifacts. Using six datasets from four different institutions digitized by different scanner systems, we systematically explore artifacts' influence on the accuracy of the pre-trained, validated, deep learning-based model for prostate cancer detection in histological slides. We provide evidence that any histological artifact dependent on severity can lead to a substantial loss in model performance. Strategies for the prevention of diagnostic model accuracy losses in the context of artifacts are warranted. Stress-testing of diagnostic models using synthetically generated artifacts might be an essential step during clinical validation of deep learning-based algorithms.

在知镜精读原文来源DOI 原文

知镜提供医学文献检索、阅读笔记、人体图谱、统计绘图与研究复现工具。